中文版 | English
Title

Design of low wear artificial hip joint considering 3D physiological loading and motion

Author
Corresponding AuthorZhang,Liangchi
Publication Years
2023-06-15
DOI
Source Title
ISSN
0043-1648
Volume523
Abstract
Wear of the bearing surfaces of an artificial hip joint (AHJ) is one of the major causes to the premature failure of the prosthesis. Any design aiming at the surface wear reduction is of significance and the first primary understanding that should be achieved is to clarify the variation of the contact trajectories and the variation of the contact stresses and areas between the femoral head and acetabular cup of an AHJ while a person is walking or running. The purpose of present work is to develop an effective mechanism model to investigate the wear at the bearing surfaces of a hip joint prosthesis under the three-dimensional motion and loading conditions under patient's walking activities. The femoral heads and acetabular cups of various dimensions were constructed by the finite element method to explore the effect of design parameters on the contact wear of their bearing surfaces. For an accurate prediction, the trajectory of the contact area in the bearing surfaces was analyzed, showing the variations in contact radius and contact stress. It was found that the sliding trajectory on the acetabular cup mainly concentrated in some specific regions. After 10 cycles of gait walking, an AHJ with thicker cup thickness or smaller femoral head radius would have less volumetric wear, whereas that with thinner cup thickness or larger femoral head radius would have less linear wear.
Keywords
URL[Source Record]
Language
English
SUSTech Authorship
Corresponding
Funding Project
National Natural Science Foundation of China[52293401];
ESI Research Field
MATERIALS SCIENCE
Scopus EID
2-s2.0-85151453503
Data Source
Scopus
Citation statistics
Cited Times [WOS]:0
Document TypeJournal Article
Identifierhttp://kc.sustech.edu.cn/handle/2SGJ60CL/524108
DepartmentInstitute for Manufacturing Innovation
工学院_力学与航空航天工程系
Affiliation
1.Shenzhen Key Laboratory of Cross-scale Manufacturing Mechanics,Shenzhen,Guangdong,518055,China
2.SUSTech Institute for Manufacturing Innovation,Shenzhen,Guangdong,518055,China
3.Department of Mechanics and Aerospace Engineering,Southern University of Science and Technology,Shenzhen,Guangdong,518055,China
First Author AffilicationInstitute for Manufacturing Innovation;  Department of Mechanics and Aerospace Engineering
Corresponding Author AffilicationInstitute for Manufacturing Innovation;  Department of Mechanics and Aerospace Engineering
Recommended Citation
GB/T 7714
Yu,Zhiyuan,Zhang,Liangchi. Design of low wear artificial hip joint considering 3D physiological loading and motion[J]. Wear,2023,523.
APA
Yu,Zhiyuan,&Zhang,Liangchi.(2023).Design of low wear artificial hip joint considering 3D physiological loading and motion.Wear,523.
MLA
Yu,Zhiyuan,et al."Design of low wear artificial hip joint considering 3D physiological loading and motion".Wear 523(2023).
Files in This Item:
There are no files associated with this item.
Related Services
Recommend this item
Bookmark
Usage statistics
Export to Endnote
Export to Excel
Export to Csv
Altmetrics Score
Google Scholar
Similar articles in Google Scholar
[Yu,Zhiyuan]'s Articles
[Zhang,Liangchi]'s Articles
Baidu Scholar
Similar articles in Baidu Scholar
[Yu,Zhiyuan]'s Articles
[Zhang,Liangchi]'s Articles
Bing Scholar
Similar articles in Bing Scholar
[Yu,Zhiyuan]'s Articles
[Zhang,Liangchi]'s Articles
Terms of Use
No data!
Social Bookmark/Share
No comment.

Items in the repository are protected by copyright, with all rights reserved, unless otherwise indicated.