中文版 | English
Title

Accurate measurement of magnetic resonance parkinsonism index by a fully automatic and deep learning quantification pipeline

Author
Corresponding AuthorQin,Yuanyuan; Tang,Xiaoying
Publication Years
2023
DOI
Source Title
ISSN
0938-7994
EISSN
1432-1084
Abstract
Objectives: This study aims at a fully automatic pipeline for measuring the magnetic resonance parkinsonism index (MRPI) using deep learning methods. Methods: MRPI is defined as the product of the pons area to the midbrain area ratio and the middle cerebellar peduncle (MCP) width to the superior cerebellar peduncle (SCP) width ratio. In our proposed pipeline, we first used nnUNet to segment the brainstem and then employed HRNet to identify two key boundary points so as to sub-divide the whole brainstem into midbrain and pons. HRNet was also employed to predict the MCP endpoints for measuring the MCP width. Finally, we segmented the SCP on an oblique coronal plane and calculated its width. A total of 400 T1-weighted magnetic resonance images (MRIs) were used to train the nnUNet and HRNet models. Five-fold cross-validation was conducted to evaluate our proposed pipeline’s performance on the training dataset. We also evaluated the performance of our proposed pipeline on three external datasets. Two of them had two raters manually measuring the MRPI values, providing insights into automatic accuracy versus inter-rater variability. Results: We obtained average absolute percentage errors (APEs) of 17.21%, 18.17%, 20.83%, and 22.83% on the training dataset and the three external validation datasets, while the inter-rater average APE measured on the first two external validation datasets was 11.31%. Our proposed pipeline significantly improved the MRPI quantification accuracy over a representative state-of-the-art traditional approach (p < 0.001). Conclusion: The proposed automatic pipeline can accurately predict MRPI that is comparable with manual measurement. Clinical relevance statement: This study presents an automated magnetic resonance parkinsonism index measurement tool that can analyze large amounts of magnetic resonance images, enhance the efficiency of Parkinsonism-Plus syndrome diagnosis, reduce the workload of clinicians, and minimize the impact of human factors on diagnosis. Key Points: • We propose an automatic pipeline for measuring the magnetic resonance parkinsonism index from magnetic resonance images. • The effectiveness of the proposed pipeline is successfully established on multiple datasets and comparisons with inter-rater measurements. • The proposed pipeline significantly outperforms a state-of-the-art quantification approach, being much closer to ground truth.
Keywords
URL[Source Record]
Indexed By
Language
English
SUSTech Authorship
First ; Corresponding
WOS Research Area
Radiology, Nuclear Medicine & Medical Imaging
WOS Subject
Radiology, Nuclear Medicine & Medical Imaging
WOS Accession No
WOS:001079198900001
Publisher
ESI Research Field
CLINICAL MEDICINE
Scopus EID
2-s2.0-85165915517
Data Source
Scopus
Citation statistics
Cited Times [WOS]:0
Document TypeJournal Article
Identifierhttp://kc.sustech.edu.cn/handle/2SGJ60CL/560205
DepartmentCollege of Engineering
工学院_电子与电气工程系
Affiliation
1.Department of Electronic and Electrical Engineering,College of Engineering,Southern University of Science and Technology,Shenzhen,Xili, Nanshan,518055,China
2.Department of Radiology,Tongji Hospital,Tongji Medical College,Huazhong University of Science and Technology,Wuhan,Jiefang Avenue,430030,China
3.Jiaxing Research Institute,Southern University of Science and Technology,Jiaxing,China
First Author AffilicationCollege of Engineering;  Department of Electrical and Electronic Engineering
Corresponding Author AffilicationCollege of Engineering;  Department of Electrical and Electronic Engineering;  Southern University of Science and Technology
First Author's First AffilicationCollege of Engineering;  Department of Electrical and Electronic Engineering
Recommended Citation
GB/T 7714
Sun,Fuhai,Lyu,Junyan,Jian,Si,et al. Accurate measurement of magnetic resonance parkinsonism index by a fully automatic and deep learning quantification pipeline[J]. European Radiology,2023.
APA
Sun,Fuhai,Lyu,Junyan,Jian,Si,Qin,Yuanyuan,&Tang,Xiaoying.(2023).Accurate measurement of magnetic resonance parkinsonism index by a fully automatic and deep learning quantification pipeline.European Radiology.
MLA
Sun,Fuhai,et al."Accurate measurement of magnetic resonance parkinsonism index by a fully automatic and deep learning quantification pipeline".European Radiology (2023).
Files in This Item:
There are no files associated with this item.
Related Services
Fulltext link
Recommend this item
Bookmark
Usage statistics
Export to Endnote
Export to Excel
Export to Csv
Altmetrics Score
Google Scholar
Similar articles in Google Scholar
[Sun,Fuhai]'s Articles
[Lyu,Junyan]'s Articles
[Jian,Si]'s Articles
Baidu Scholar
Similar articles in Baidu Scholar
[Sun,Fuhai]'s Articles
[Lyu,Junyan]'s Articles
[Jian,Si]'s Articles
Bing Scholar
Similar articles in Bing Scholar
[Sun,Fuhai]'s Articles
[Lyu,Junyan]'s Articles
[Jian,Si]'s Articles
Terms of Use
No data!
Social Bookmark/Share
No comment.

Items in the repository are protected by copyright, with all rights reserved, unless otherwise indicated.